Part Number 037-228

Power Autotransforme Transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
037-228
Demil:
No
Shelf Life:
UOM:
NIIN:
001757289
NSN
National Stock Number:
5950-00-175-7289 5950001757289
TXT
Description:
Power Autotransforme Transformer
INC
INC
Item Name Code:
36166
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.375 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.500 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, fixed autotransformer type single component
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
115.00 ac volts single component single primary input
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
17.00 ac volts single component single primary output and 20.00 ac volts single component single primary output and 23.00 ac volts single component single primary output and 27.00 ac volts single component single primary output and 32.00 ac volts single component single primary output and 38.00 ac volts single component single primary output and 45.00 ac volts single component single primary output and 53.00 ac volts single component single primary output and 62.00 ac volts single component single primary output and 72.00 ac volts single component single primary output and 84.00 ac volts single component single primary output and 98.00 ac volts single component single primary output and 115.00 ac volts single component single primary output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
14 wire lead

Similar Power Autotransforme Transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide