Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Terminal Board
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.AAMA
Mounting Hole Diameter:
0.125 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Barrier type
MRC:
The number of terminal rows or terminal provisions included on the item.ABCS
Terminal Row Quantity:
2
MRC:
The center to center distance between terminals.ABCT
Center To Center Distance Between Terminals:
0.250 inches
MRC:
The distance between the terminal row centers.ABCU
Distance Between Terminal Row Centers:
0.250 inches
MRC:
The structural characteristic(s) of the board.ABCX
Board Construction:
Hollow construction without insulated strip
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.250 inches
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.250 inches
Distance From Bottom Edge Of Terminal Board To Center Of Mounting Hole:
0.188 inches
Distance From Left Edge Of Terminal Board To Center Of First Mounting Facility:
0.125 inches
Boardlength:
3.500 inches
Boardheight:
0.312 inches
Board Height Excluding Terminals:
0.312 inches
Base Thickness:
0.219 inches
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
5.0
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The number of terminal connecting links furnished with the item.CQCZ
Terminal Connecting Link Quantity:
12 single
MRC:
Indicates the type of nonfeedthru terminal furnished with the item.CRNL
Nonfeedthru Terminal Type:
859 single
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
Indicates the type of terminal connecting link/s/ furnished with the item.CSCR
Terminal Connecting Link Type:
1 single
MRC:
The number of nonfeedthru terminals furnished with the item.CSCS
Nonfeedthru Terminal Quantity:
12 single
MRC:
The arrangement of terminal positions on the item.CWLG
Terminal Pattern Arrangement:
Multi-row
MRC:
The design of the terminal.CWLN
Terminal Design:
Linked nonfeedthru
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic diallyl phthalate board and glass fiber board
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-p-19833, type gdi-30f military specification single material response board
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Nickel terminals
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Quality controlled for polaris