Part Number 0498001-16

Power Supply

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
0498001-16
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
013568803

Part Information
Electrostatic sensitive device, undervoltage protector, surge protect

NSN
National Stock Number:
6130-01-356-8803 6130013568803
TXT
Description:
Power Supply
INC
INC
Item Name Code:
00740
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.360 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus proof
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/alq17 (v) 2
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
55000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
118.0 ac volts 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
205.0 ac volts 1st alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
16.0 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
28.0 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-16.0 dc volts 6th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-40.0 dc volts 7th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
40.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 5th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
9.0 dc volts 4th power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
380.0 hertz single operating power rqmt and 420.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-54.0/+75.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Over voltage protector
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-5.0 dc amperes 6th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-7.0 dc amperes 7th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
45.0 dc amperes 5th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
5.0 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
7.0 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
7.5 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
8.0 dc amperes 4th power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Connector, receptacle single power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Connector, receptacle single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
3 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Air cooled
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
80.0
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by source control drawing

Similar Power Supplies

« Converters Electrical Nonrotating Catalog
Compare Now »
Clear | Hide