Part Number 05715P1

Stepping Switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
05715p1
Demil:
No
Shelf Life:
UOM:
NIIN:
008822069
NSN
National Stock Number:
5930-00-882-2069 5930008822069
TXT
Description:
Stepping Switch
INC
INC
Item Name Code:
26954
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.062 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.093 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The means of attaching the item.ADJH
Mounting Method:
Bracket
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
2 no. 8 /0.164 in./-32 thd mtg holes on 5.312 in. Centers
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
24.0 volts
MRC:
The means of restoring the item to a homing position.ANZW
Homing Method:
Through off-normal springs
MRC:
The number of bank levels provided.ANZX
Bank Level Quantity:
9
MRC:
The number of contact/s/ /point/ provided in each bank level.ANZY
Contact Quantity Per Bank Level:
26
MRC:
The number of wiper contacts provided in each bank level.ANZZ
Wiper Contact Quantity Per Bank Level:
1
MRC:
The amount of current for which the contact/s/ was designed.APAA
Contact Current Rating:
3.0 amperes
MRC:
Indicates the type of contact/s/ used.APAB
Contact Type:
Bridging and nonbridging
MRC:
The number of bridging levels provided.APAC
Bridging Level Quantity:
3
MRC:
The number of nonbridging levels provided.APAD
Nonbridging Level Quantity:
6
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
Indicates the type of coil used.APAG
Coil Type:
Drive
MRC:
The basic form of the auxiliary off-normal contact arrangement.APCD
Auxiliary Off-normal Contact Arrangement:
2c
MRC:
The basic form of the auxiliary interrupter contact arrangement.APCE
Auxiliary Interrupter Contact Arrangement:
2b
MRC:
An indication of the stepping direction.APCJ
Stepping Direction:
Unidirectional

Similar Stepping Switches

« Switches Catalog
Compare Now »
Clear | Hide