Part Number 063551-0001

Circuit Breaker Subassembly

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
063551-0001
Demil:
No
Shelf Life:
UOM:
NIIN:
012298536

Part Information
Load center rated 25 amps when a1 wire is used

NSN
National Stock Number:
5925-01-229-8536 5925012298536
TXT
Description:
Circuit Breaker Subassembly
INC
INC
Item Name Code:
37465
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
3.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.720 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.810 inches
MRC:
A designation of the standard mounting facility arrangement provided.AESL
Standard Mounting Pattern Designator:
4 point-rectangular
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
Indicates the type of system in which the item is designed to be used.AGEJ
System For Which Designed:
Three wire single phase
MRC:
The means of attaching the item.AXGY
Mounting Method:
Slot
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
The maximum current rating of the main line,expressed in amperes.BFYC
Main Line Maximum Current Rating In Amps:
30.0
MRC:
The maximum alternating current voltage rating of the main line,expressed in volts.BFYD
Main Line Maximum Ac Voltage Rating In Volts:
240.0
MRC:
Indicates the type and number of circuit breakers the item can accommodateCWXW
Circuit Breaker Type And Quantity Accommodated:
2 single pole
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular, surface mounting

Similar Circuit Breaker Subassemblies

« Circuit Breakers Catalog
Compare Now »
Clear | Hide