Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
0661630005
Demil:
No
Shelf Life:
UOM:
NIIN:
014775531

Part Information
Hermetically sealed; total submersibility; insulation resistance 1000.0 megohms min. At 500 vdc; breakdown voltage 500.0 volts rms 60.0 hertz between all mutually insulated points; temp. Range minus 55.0 to plus 71.0 deg. C; rated life 100000 operations min. At max. Rated load; terminals 0.030 in. Dia. Located on 0.200 in. Grid pattern; configuration 2 form c, double pole double throw; contact resistance 50.0 milliohms max. Initial measured at max. Rated load; sensitivity of 350.0 milliwatts at plus 25.0 deg. C; power 660.0 milliwatts at plus 25.0 deg. C; 24 volt coil; weight is 0.035 ounces

NSN
National Stock Number:
5945-01-477-5531 5945014775531
TXT
Description:
Electromagnetic Relay
INC
INC
Item Name Code:
32512
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
Between 60.0 and 400.0
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.0003 seconds fixed release time
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.0004 seconds fixed operate time
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
0.5 amperes ac resistive load and 2.0 amperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 30.0 dc
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contacts gold and contacts silver