Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Voltmeter
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Dc
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.047 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.030 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.030 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
4 single indicator single range
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
984 propulsion system
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-1.5/+1.5 at full scale single indicator single range
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
2.022 inches
MRC:
The length of a straight line which passes through the center of the meter body behind the mounting flange, and terminates at the circumference.APSW
Meter Body Diameter Behind Mounting Flange:
3.097 inches
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator single range
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black single indicator single range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator single range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 volts, dc single indicator single range
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
4 threaded stud
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular flush mtg