Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Nonind Wire Wound Fixed Resistor
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.AAPE
Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius:
-5.0/+5.0
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
21.000 ohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-0.050/+0.050
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
65.0
MRC:
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.AAQG
Ambient Tempurature In Deg Celsius At Zero Percent Rated Power:
145.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-55.0/+125.0
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.000 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
0.250 free air