Part Number 090-00028

Electrical Frequency Meter
Stock Availability  condition code chart

Part number 090-00028 is in stock in the following quantities and conditions.

  • NS: 1
  • AR: 1
  • OH: 1
  • SV: 1

Note: Availability of this item was last updated 04/07/2021 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

Images

Reference images of this part
Picture of NSN 6625-01-141-8475
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
090-00028
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
011418475
NSN
National Stock Number:
6625-01-141-8475 6625011418475
TXT
Description:
Electrical Frequency Meter
INC
INC
Item Name Code:
16454
INC
COM
Compliance:
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.093 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.375 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.375 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.421 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.421 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.312 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Shock resistant and watertight
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Nut 8; lockwasher 2; flat washer 10
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Four hole/stud rectangular/square
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-1.5/+1.5 at full scale single indicator single range
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
2.816 inches
MRC:
The length of a straight line which passes through the center of the meter body behind the mounting flange, and terminates at the circumference.APSW
Meter Body Diameter Behind Mounting Flange:
3.930 inches
MRC:
Indicates the type of movement provided.AQEC
Movement Type:
Moving coil, permanent magnet
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator single range
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black single indicator single range
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 screw and 4 unthreaded hole
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Terminal
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Zero adjuster
MRC:
The means employed to suspend the movement of the item.CTQL
Movement Suspension Method:
Jewel pivot base
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 threaded stud
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum and steel
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular flush mtg
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set, elect. Equip.

Similar Electrical Frequency Meters

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide