Part Number 10-1011-501

Liquid Level Switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
10-1011-501
Demil:
No
Shelf Life:
UOM:
NIIN:
008354326
NSN
National Stock Number:
5930-00-835-4326 5930008354326
TXT
Description:
Liquid Level Switch
INC
INC
Item Name Code:
37187
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.100 inches
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.810 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Connector receptacle
MRC:
The specification,standard,or manufacturer's number or symbol used to identify the connector.AGBG
Connector Identification:
10-160150-3
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
6.0 amperes resistive load
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -65.0 degrees fahrenheit and 160.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Dt, 3 position, 2 position, momentary
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Aircraft fuel
MRC:
The aircraft fuel for which the item is designed.BJKJ
Aircraft Fuel For Which Designed:
All
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
Between 2.000 inches and 2.500 inches

Similar Liquid Level Switches

« Switches Catalog
Compare Now »
Clear | Hide