Part Number 10035747-101

Pulse Transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
10035747-101
Demil:
No
Shelf Life:
UOM:
NIIN:
005644348
NSN
National Stock Number:
5950-00-564-4348 5950005644348
TXT
Description:
Pulse Transformer
INC
INC
Item Name Code:
00208
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
2.50 microhenries single component single secondary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
4.00 microhenries single component single primary
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
5.0 kilohertz single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.430 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.500 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
500.0 milliamperes dc single component single primary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
500.0 milliamperes dc single component single secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead

Similar Pulse Transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide