Part Number 100541

Control-monitor

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
100541
Demil:
No
Shelf Life:
UOM:
NIIN:
001624469
NSN
National Stock Number:
5895-00-162-4469 5895001624469
TXT
Description:
Control-monitor
INC
INC
Item Name Code:
00906
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
21.125 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.312 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.625 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
117.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz 1st alternate operating power rqmt
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Control-monitor
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
C2124a/fpn33
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Controls operation of ventilating fan, ac power to major components of receiver-transmitter group, ac power to actuator antenna drives of the antenna group
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The number of signals which the item is capable of receiving.AMMD
Input Signal Quantity:
2
MRC:
The means used for monitoring the item.AWMS
Monitoring Method:
Visual
MRC:
Indicates the type of input signal.AWNS
Input Signal Type:
Vided pulse system trigger
MRC:
The number of alternating current phases.FAAZ
Phase:
Single