Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Calibration facilities
NSN
National Stock Number:
TXT
Description:
Multimeter
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac and dc
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.100 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.930 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.180 inches
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+50.000/+400.000 hertz
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
4.840 inches
MRC:
A measurement taken at right angles to the length of the meter body behind the mounting flange, in distinction from thickness.APSY
Meter Body Width Behind Mounting Flange:
3.920 inches
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 bezel and 2 clamp
MRC:
Indicates the type of display provided.BFQN
Display Type:
Light emitting diode
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
3-1/2
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+0.5 decibels single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-0.1999/+0.1999 volts, dc single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-0.1999/+0.1999 volts, root mean square single indicator 11th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1.999/+1.999 volts, root mean square single indicator 12th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1.999/+1.999 volts, dc single indicator 7th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-19.99/+19.99 volts, dc single indicator 8th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-19.99/+19.99 volts, root mean square single indicator 13th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 volts, dc single indicator 9th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 volts, root mean square single indicator 14th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-600.0/+600.0 volts, dc single indicator 10th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-600.0/+600.0 volts, root mean square single indicator 15th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+5.0 decibels single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+50.0 decibels single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+500.0 decibels single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+625.0 decibels single indicator 5th range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Terminal
Meter Body Height Behind Mounting Flange:
1.670 inches
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Zero adjuster
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading porm 1 digit single indicator 12th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading porm 1 digit single indicator 7th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.3 pct of reading porm 1 digit single indicator 14th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.3 pct of reading porm 1 digit single indicator 8th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.3 pct of reading porm 1 digit single indicator 9th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.3 pct of reading porm 1 digit single indicator 13th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.2 pct of reading porm 1 digit single indicator 10th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.2 pct of reading porm 1 digit single indicator 11th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.2 pct of reading porm 1 digit single indicator 15th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.2 pct of reading porm 1 digit single indicator 6th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 db single indicator 1st range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 db single indicator 2nd range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 db single indicator 3rd range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 db single indicator 4th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 db single indicator 5th range
MRC:
The hue or tint of the display.CTQH
Display Color:
Red single indicator all ranges
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 connector, plug
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular flush mtg
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set, elect. Equip.