Contact to contact location designator: 17 and 18
NSN
National Stock Number:
TXT
Description:
Electrical Receptacle Connector
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight edge type w/mounting flange
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.726 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.932 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.655 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Salt water resistant and vibration resistant
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
Between 0.123 inches and 0.133 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
Between 2.411 inches and 2.421 inches
Board Accommodated Length:
1.945 inches single board and 1.955 inches single board
Board Accommodated Length:
1.945 inches and 1.955 inches single board
Board Accommodated Width:
Between 0.071 inches and 0.081 inches
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
Switching contacts inserted board single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Removable single mating end single contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
5.0 single mating end single contact grouping
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
Fixed contact to contact
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the contact is fabricated.CQTZ
Contact Material:
Copper alloy single mating end single contact grouping
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.CQYH
Contact Surface Treatment:
Gold single mating end single contact grouping and nickel single mating end single contact grouping
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.CQYH
Contact Surface Treatment:
Gold and nickel single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the insert is fabricated.CQZG
Insert Material:
Plastic diallyl phthalate single mating end
MRC:
A designation which is used to indicate one fixed contact position and the opposite fixed contact position of a polarizing key.CRNC
Unable To Decode:
Unable to decode and unable to decode
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Crnc
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Crimp single mating end single contact grouping
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the contact material.CSGF
Contact Material Specification:
Qq-b-750, comp a federal specification single material response single mating end single contact grouping
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the insert material.CTKL
Insert Material Specification:
Mil-m-14, ty sdg-f military specification single material response single mating end
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
30 single mating end single contact grouping
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Leaf spring single mating end single contact grouping
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
18876-10243528 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)