Part Number 1037A826REV2

Power Transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
1037a826rev2
Demil:
No
Shelf Life:
UOM:
NIIN:
000379549
NSN
National Stock Number:
5950-00-037-9549 5950000379549
TXT
Description:
Power Transformer
INC
INC
Item Name Code:
32496
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 1.594 inches and 2.094 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
380.0 hertz single component and 1.0 kilohertz single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.469 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.344 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 2 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
30.0 milliamperes dc all components all secondary
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
28.00 ac volts single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
6.30 ac pounds per hour wet single component all secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 wire lead
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Material will be in accordance with ships parts control center activity hx quality control, manufacturing and testing specifications

Similar Power Transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide