Part Number 104-1944

Power Transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
104-1944
Demil:
No
Shelf Life:
UOM:
NIIN:
003137245

Part Information
Weapon system essential

NSN
National Stock Number:
5950-00-313-7245 5950003137245
TXT
Description:
Power Transformer
INC
INC
Item Name Code:
32496
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.812 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.000 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.203 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz single component and 60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
4.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.125 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
3.562 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Forrestal class cv; spruance class dd (963); impeccable class t-agos 23; virginia class cgn (41); arleigh burke class ddg; oliver perry class ffg; kidd class ddg; ticonderoga class cg (47); wasp class lhd; nimitz class cvn
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Strap single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component and 1 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
0.5681 amperes ac single component 2nd primary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
250.0 volts-amperes single component single secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
250.0 volts-amperes single component 1st primary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
250.0 volts-amperes single component 2nd primary
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
110.00 ac pounds per hour wet single component single secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
220.00 ac pounds per hour wet single component 1st primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
440.00 ac pounds per hour wet single component 2nd primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 threaded hole

Similar Power Transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide