Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Radio Frequency Interfere Filter
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
9.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.170 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
6.000 inches
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
10.0 1st radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
15.0 2nd radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
2.0 3rd radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
2.8 4th radio interference
MRC:
The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
Maximum Voltage Drop Per Function:
27.0 millivolts dc 4th radio interference
MRC:
The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
Maximum Voltage Drop Per Function:
33.0 millivolts dc 1st radio interference
MRC:
The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
Maximum Voltage Drop Per Function:
40.0 millivolts dc 3rd radio interference
MRC:
The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
Maximum Voltage Drop Per Function:
7.0 millivolts dc 2nd radio interference
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
15.0 volts dc 3rd radio interference 3rd function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
28.0 volts dc 1st radio interference 1st function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
5.05 volts dc 2nd radio interference 2nd function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
12.0 volts dc 4th radio interference 4th function
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on one surface