Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
1048-2
Demil:
No
Shelf Life:
UOM:
NIIN:
005404106

Part Information
For use w/ petroleum based hydraulic fluid

NSN
National Stock Number:
4820-00-540-4106 4820005404106
TXT
Description:
Pressure And Temper Relief Valve
INC
INC
Item Name Code:
16996
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum alloy and copper alloy
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
Outside Surface Treatment:
Any acceptable
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight through w/ offset give "adql" only when both ends flanged
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
160.0 degrees fahrenheit
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal boss
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Gasket seal
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
First End Thread Class:
3b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
Indicates whether or not the third end is identical with first or second end.ACMX
Third End Relationship With Preceding Ends:
Identical with first end
MRC:
Indicates whether or not the fourth end is identical with the first,second,or third end.ACPE
Fourth End Relationship With Preceding Ends:
Identical with first end
MRC:
The distance of offset in the item.ACSX
Offset Distance:
0.375 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Piston, spring loaded
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
4
MRC:
The predetermined pressure at which the item is calibrated to open.ADSV
Opening Pressure Setting:
1600.0 pounds per square inch
MRC:
The minimum to maximum pressures at which the item may be adjusted.ADSW
Adjustable Pressure Range:
+1000.0/+2300.0 pounds per square inch
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
6.0 gallons per minute
MRC:
An indication of whether or not the temperature is adjustable.AEVX
Tempurature Adjustability:
Not adjustable
MRC:
Indicates the type of temperature control device that actuates the item.AFKX
Tempurature Control Device Type:
Thermostatic
MRC:
A designator distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CQMM
First End Thread Series Designator:
Unf
MRC:
The designation which is used for the purpose of general identification of the nominal thread size.CQYM
First End Thread Size:
0.750 inches