Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Control-indicator
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum alloy, qq-a-250/8, alloy 5052, h32
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Anodized
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
120.0 ac and 60.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Uninclosed
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
1.0
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Back
MRC:
The minimum and maximum operating limits of the item.ASXT
Operating Range:
0.025 amps to 1.0 amps
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Surface
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
1 tab solder lug and 6 threaded stud
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
11.380 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
7.120 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
5.180 inches
MRC:
The means provided to indicate data.CKQZ
Indication Method:
Receiving meter movement err-100 err-100
MRC:
The means provided to indicate data.CKQZ
Indication Method:
Transmitting meter movement err-100 err-100
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0