Sine, triangle, square, ramp, noise, si (x) /x, exponential rise & fall, heartbeat, dc volts; 12-bit 40 msa/s 16k deep arbitrary waveforms; linear & log sweeps built-in; am, fm, fsk & burst modulation built-in; hp-ib & rs-232 interfaces; 15mhz sine & square wave outputs; 3 user configurable stored states
NSN
National Stock Number:
TXT
Description:
Electronic Te Function Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
14.720 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.080 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.020 inches
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic or manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Top of cabinet/counter
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
15.0 megahertz output channel
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms output channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Operating channel digital err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Operating channel sweep err-100
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Isosceles triangular and sine and square and sawtooth
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Connector, plug front and connector, plug rear
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
45.0 single voltage and 66.0 single voltage
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
6 connector, plug external
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
100.0 single voltage and 240.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Freq specification 1 hz - 100 khz; add'l power line frequency 360 hz to 440 hz