Part Number 1114359

El Engine Starter Relay-solenoid

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
1114359
Demil:
No
Shelf Life:
UOM:
NIIN:
000185675

Part Information
Furnished with helical spring

NSN
National Stock Number:
2920-00-018-5675 2920000185675
TXT
Description:
El Engine Starter Relay-solenoid
INC
INC
Item Name Code:
17084
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.250 inches
MRC:
An indication of whether or not an item is capable of operation while submerged.AHZV
Submersibility:
Nonsubmersible
MRC:
The distance between the mounting facilities.ARKQ
Mounting Facility Spacing:
Mounting holes 2.936 in. C to c, 180 degrees apart
MRC:
The nominal value(s) of potential for which the item is rated.AWYG
Voltage Rating:
12.0 volts
MRC:
The measured distance of the plunger stroke.AXBD
Plunger Stroke Length:
0.046 inches
MRC:
An indication of whether or not engaging linkage is included.AXBE
Engaging Linkage:
Not included
MRC:
The length of a straight line which passes through the center of the unthreaded hole for the accommodated linkage,and terminates at the circumference.AXCA
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the unthreaded hole for the accommodated linkage,and terminates at the circumference.AXCA
Accommodated Linkage Unthreaded Hole Diameter:
1.000 inches
MRC:
An indication of whether or not the item includes provisions for manually closing the contacts.AXCC
Contact Manual Closing Provision:
Not included
MRC:
The number of control terminals provided.AXCD
Control Terminal Quantity:
1
MRC:
Indicates the type of control terminal/s/ provided.AXCE
Control Terminal Type:
Threaded stud
MRC:
An indication of whether or not a grounded control terminal is included.AXCF
Grounded Control Terminal:
Included
MRC:
The number of main terminals provided.AXHJ
Main Terminal Quantity:
1
MRC:
Indicates the type of main terminal/s/ provided.AXHK
Main Terminal Type:
Threaded stud
MRC:
The number of control terminals that are internally connected to the main terminals.AXHM
Control Terminal Quantity Internally Connected To Main Terminal:
1
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 hole

Similar El Engine Starter Relay-solenoids

« Nonaircraft Engine Electrical System Components Catalog
Compare Now »
Clear | Hide