National Stock Number:
TXT
Description:
Engine Generator Regulator
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
4
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Threaded stud
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.318 inches err-100 err-100
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.338 inches err-100 err-100
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.318 inches err-100 err-100
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.338 inches err-100 err-100
MRC:
A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
Mounting Slot Length:
0.443 inches err-100 err-100
MRC:
A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
Mounting Slot Length:
0.463 inches err-100 err-100
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the mounting.ADER
Mounting Style:
Two plain holes two slotted holes
Distance Between Holes Along Length:
6.000 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Corrosion resistant err-100 err-100
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus resistant err-100 err-100
MRC:
An indication of whether or not the item is provided with a self-contained shock mount.AGBC
Shock Mount:
Not provided
MRC:
An indication of whether or not shielding against radio interference is provided.ALBH
Radio Interference Shielding:
Provided
MRC:
The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
Output Voltage Rating In Volts:
28.0 err-100 err-100
MRC:
The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
Output Voltage Rating In Volts:
29.5 err-100 err-100
MRC:
The electrical voltage of the system for which the item is designed.ANYC
System Voltage Rating:
24.0
MRC:
Indicates the type of ground the electrical system utilizes.ANYD
System Ground Polarity:
Negative
MRC:
Indicates the type of device used to maintain a constant voltage.ANYE
Voltage Regulator Unit Type:
Wire wound coil
MRC:
The number of individual voltage regulator units contained in the item.ANYH
Voltage Regulator Unit Quantity:
1
MRC:
Indicates the type of device used to limit the current output to the maximum safe value.ANYJ
Current Regulator Unit Type:
Wire wound coil
MRC:
The number of individual current regulator units contained in the item.ANYK
Current Regulator Unit Quantity:
1
MRC:
The current the item will permit to pass,expressed in amperes.ANYP
Output Current Rating In Amps:
16.0 err-100 err-100
MRC:
The current the item will permit to pass,expressed in amperes.ANYP
Output Current Rating In Amps:
20.0 err-100 err-100
MRC:
Indicates the type of device used to close and open (break) the circuit.ANYR
Circuit Control Device Type:
Cutout relay
MRC:
The cut-in voltage/s/ required to close the circuit.ANYS
Cut-in Voltage Rating:
25.0 err-100 err-100
MRC:
The cut-in voltage/s/ required to close the circuit.ANYS
Cut-in Voltage Rating:
27.0 err-100 err-100
MRC:
The cutout voltage/s/ required to open /break/ the circuit.ANYX
Cutout Voltage Rating:
14.0 err-100 err-100
MRC:
The cutout voltage/s/ required to open /break/ the circuit.ANYX
Cutout Voltage Rating:
17.0 err-100 err-100
MRC:
The discharge /cutout/ current/s/ required to open /break/ the circuit,expressed in amperes.ANYZ
Cutout Current Rating In Amps:
13.0 err-100 err-100
MRC:
The discharge /cutout/ current/s/ required to open /break/ the circuit,expressed in amperes.ANYZ
Cutout Current Rating In Amps:
4.0 err-100 err-100
MRC:
An indication of whether or not a reverse current overload circuit breaker is included.ANZB
Reverse Current Overload Circuit Breaker:
Not included
MRC:
An indication of whether or not a field relay unit is included.ANZC
Field Relay Unit:
Not included
MRC:
An indication of whether or not the terminal(s) is encased.ANZE
Terminal Encasement:
Encased
MRC:
The number of conduit connection(s) provided.ANZF
Conduit Connection Quantity:
3
Center To Center Distance Between Slotted Holes Along Length:
6.000 inches
Center To Center Distance Between Slotted Holes And Plain Holes Along Width:
6.000 inches