Part Number 1123-500

Flow Rate Indicating Meter
Stock Availability  condition code chart

Part number 1123-500 is in stock in the following quantities and conditions.

  • NE: 1
  • NS: 1
  • AR: 1

Note: Availability of this item was last updated 04/18/2024 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
1123-500
Demil:
No
Shelf Life:
UOM:
NIIN:
005266561
NSN
National Stock Number:
6680-00-526-6561 6680005266561
TXT
Description:
Flow Rate Indicating Meter
INC
INC
Item Name Code:
38346
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
21.250 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Hose nipple
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Usaf f105 aircraft portable aircraft cabin leakage tester model mbi-mb3
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Sight windows in extension chamber
MRC:
An indication of the type of meter.ANTH
Meter Type:
Float
MRC:
Indicates the design type of the item.APGF
Design Type:
Glass
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Cfm
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Direct capacity reading
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Glass
MRC:
The means of attaching the item.AXGY
Mounting Method:
Direct line
MRC:
Indicates the location of the unit.AYTM
Unit Location:
Upper right side
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+0.0/+260.0
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
2-1/4 in. Un3b
MRC:
The length of a straight line which passes through the center of an outlet bolt circle,and terminates at the circumference.BHCS
Outlet Bolt Circle Diameter:
5.500 inches
MRC:
The number of outlet bolt hole(s) on the item.BHCT
Outlet Bolt Hole Quantity:
4
MRC:
The length of a straight line which passes through the center of an outlet bolt hole,and terminates at the circumference.BHCW
Outlet Bolt Hole Diameter:
0.406 inches
MRC:
Indicates the type of float used.BHSQ
Float Type:
Free
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Steel
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
3.000 inch hose nipple
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
The smallest increment of graduation on the dial scale.CPZJ
Dial Scale Smallest Increment:
10 cfm
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Not included
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary or swivel
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included

Similar Flow Rate Indicating Meters

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments Catalog
Compare Now »
Clear | Hide