Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Relay-switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
12.782 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.421 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.470 inches
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Magnetic
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three no. 6-32 thd studs irregularly spaced
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Dc
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Dc
MRC:
The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
Maximum Voltage Rating In Volts:
29.0
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
10.0 amperes resistive
MRC:
The maximum amount of current for which the item is designed,expressed in amperes.APGX
Maximum Current Rating In Amps:
10.0 resistive
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
29.0 volts
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Dc
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
28.0
MRC:
The amount of operating current,expressed in amperes.APHB
Operating Current In Amps:
0.2
MRC:
The maximum opposition to the flow of direct current,expressed in ohms.APJX
Maximum Dc Resistance In Ohms:
160.0
MRC:
The number of noninductive windings.APJY
Err Default:
Err default
MRC:
The number of noninductive windings.APJY
Noninductive Winding Quantity:
1
MRC:
The designation that identifies the schematic diagram of the electrical configuration of a switch.APLQ
Switch Contact Arrangement:
4pdtno
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the circuit overload protector.APLY
Err Default:
Err default
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the circuit overload protector.APLY
Circuit Overload Protector Contact Arrangement:
4pdtno
MRC:
The value/s/,or range of values,of direct current potential for which the continuous load is rated.APMC
Err Default:
Err default
MRC:
The value/s/,or range of values,of direct current potential for which the continuous load is rated.APMC
Continuous Load Dc Voltage Rating:
22.5 volts
MRC:
The direct current rating of the continuous load.APMD
Err Default:
Err default
MRC:
The direct current rating of the continuous load.APMD
Continuous Load Dc Current Rating:
40.0 amperes
MRC:
The interrupting capacity of the item.APME
Err Default:
Err default
MRC:
The interrupting capacity of the item.APME
Interrupting Capacity:
50.0 amperes
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
4pdtno