Part Number 119-0095-05

Radio Frequency Interfere Filter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
119-0095-05
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
001074345
NSN
National Stock Number:
5915-00-107-4345 5915001074345
TXT
Description:
Radio Frequency Interfere Filter
INC
INC
Item Name Code:
00765
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 1.470 inches and 1.530 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 3.082 inches and 3.202 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 1.870 inches and 2.030 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
Between 1.220 inches and 1.280 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 2.460 inches and 2.520 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.204 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+55.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0 to 85.0 degrees celsius
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
250.0
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 1st radio interference
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 2nd radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
1.0 1st radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
1.0 1st radio interference 1st function
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
MRC:
None.AHBX
Distance Between Mounting Surface And Lower End:
Between 0.622 inches and 0.682 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
2 tab, solder lug output 2nd function
MRC:
The maximum alternating current root mean square voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CQDZ
Maximum Dielectric Withstanding Ac Rms Voltage:
900.0 volts at sea level
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
250.0 volts ac 1st radio interference 1st function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
250.0 volts ac 2nd radio interference 2nd function
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Round terminal/terminals on opposite surfaces