Part Number 11DCS229

Automatic Water Supply System

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
11dcs229
Demil:
No
Shelf Life:
UOM:
NIIN:
003682958
NSN
National Stock Number:
4320-00-368-2958 4320003682958
TXT
Description:
Automatic Water Supply System
INC
INC
Item Name Code:
19731
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
40.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
39.125 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
29.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
An indication of whether or not a self-priming feature is included.AHZH
Err Default:
Err default
MRC:
An indication of whether or not a self-priming feature is included.AHZH
Self-priming Feature:
Included
MRC:
The rated horsepower of the prime mover.AHZX
Prime Mover Horsepower Rating:
0.750
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the capacity of the tank.AMKA
Tank Capacity:
50.0 gallons
MRC:
Indicates the type of pump provided.AXEL
Pump Type:
Centrifugal
MRC:
The maximum output delivered by the item per hour.AYCG
Err Default:
Err default
MRC:
The maximum output delivered by the item per hour.AYCG
Delivery Rate Per Hour:
600.0 gallons
MRC:
An indication of whether or not a peripheral flow feature is included.AYCK
Err Default:
Err default
MRC:
An indication of whether or not a peripheral flow feature is included.AYCK
Peripheral Flow Feature:
Included
MRC:
Designates the size of the relative or proportionate dimension(s) of the inlet suction.AYCL
Err Default:
Err default
MRC:
Designates the size of the relative or proportionate dimension(s) of the inlet suction.AYCL
Inlet Suction Size:
1.250 inches
MRC:
An indication of whether or not a corrosion resistant feature is included.AYCM
Corrosion Resistant Feature:
Included
MRC:
An indication of whether or not an automatic air volume control feature is included.AYCN
Err Default:
Err default
MRC:
An indication of whether or not an automatic air volume control feature is included.AYCN
Automatic Air Volume Control Feature:
Included
MRC:
An indication of whether or not a unit mounted feature is included.AYCP
Err Default:
Err default
MRC:
An indication of whether or not a unit mounted feature is included.AYCP
Unit Mounted Feature:
Not included
MRC:
The number of service connections provided.AYCQ
Err Default:
Err default
MRC:
The number of service connections provided.AYCQ
Service Connection Quantity:
1
MRC:
Designates the size of the relative or proportionate dimension(s) of the service connection.AYCR
Err Default:
Err default
MRC:
Designates the size of the relative or proportionate dimension(s) of the service connection.AYCR
Service Connection Size:
1.250 inches
MRC:
An indication of whether or not a deep well conversion feature is included.AYCS
Err Default:
Err default
MRC:
An indication of whether or not a deep well conversion feature is included.AYCS
Deep Well Conversion Feature:
Not included
MRC:
An indication of whether or not a salt water service feature is included.AYCT
Err Default:
Err default
MRC:
An indication of whether or not a salt water service feature is included.AYCT
Salt Water Service Feature:
Not included
MRC:
The position of the tank on the item.AZGN
Err Default:
Err default
MRC:
The position of the tank on the item.AZGN
Tank Position:
Vertical
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0

Similar Automatic Water Supply Systems

« Power and Hand Pumps Catalog
Compare Now »
Clear | Hide