Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Relay-switch
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac and dc
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Rotary
MRC:
Indicates the type of action provided.AMWM
Action Type:
Instantaneous
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Armature
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac and dc
MRC:
The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
Maximum Voltage Rating In Volts:
500.0
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Ac and dc
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
Between 7.0 and 500.0
MRC:
The amount of operating current,expressed in amperes.APHB
Operating Current In Amps:
Between 0.2 and 2.0
MRC:
The maximum opposition to the flow of direct current,expressed in ohms.APJX
Maximum Dc Resistance In Ohms:
103.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of a switch.APLQ
Switch Contact Arrangement:
10spstno
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
600.0
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
6.0 amperes
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
50.0 amperes
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
600.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the circuit overload protector.APLY
Err Default:
Err default
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the circuit overload protector.APLY
Circuit Overload Protector Contact Arrangement:
2spstnc
MRC:
The interrupting capacity of the item.APME
Err Default:
Err default
MRC:
The interrupting capacity of the item.APME
Interrupting Capacity:
2.5 amperes
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
2spstnc