Part Number 13-620-90

Ph Electrode

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
13-620-90
Demil:
No
Shelf Life:
UOM:
NIIN:
010155980

Part Information
For use in routine ph and titration measurements in aqueous and nonaqueous samples

NSN
National Stock Number:
6630-01-015-5980 6630010155980
TXT
Description:
Ph Electrode
INC
INC
Item Name Code:
42791
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
10.0 millimeters
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
140.0 millimeters
MRC:
A measurement of the longest dimension of an electrical lead,in distinction from width.AWCH
Electrical Lead Length:
30.000 inches
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Integral preconditioning solution vial and shielded
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Glass
MRC:
Indicates the type of instrument that the item will be used with,as suggested by either government specification or manufacturer.CYHA
Instrument Type For Which Designed:
No instrument designation
MRC:
The name of the item,other than a functional or application name,that industry has assigned.CYHC
Industry Designated Name:
General purpose combination
MRC:
An indication of the ph minimum and maximum testing/measuring limits of the item.CYHD
Ph Measurement Range:
+0.00/+14.00
MRC:
The minus and/or plus degrees of temperature the item can withstand without giving erroneous assay data.CYHE
Operating Temperature Range:
5.0 degrees celsius minus and 80.0 degrees celsius plus
MRC:
Indicates the type of junction employed in the item,to prevent unwanted ion interference.CYHG
Err Default:
Err default
MRC:
Indicates the type of internal electrode element employed to read a specific ion concentration in a sample/specimen or solution.CYHH
Internal Reference Element Type:
Silver/silver chloride
MRC:
Indicates the type of electrical lead connector included with the item.CYHJ
Err Default:
Err default
MRC:
Indicates the type and concentration of a solution needed to activate the item.CYHK
Err Default:
Err default

Similar Ph Electrodes

« Chemical Analysis Instruments Catalog
Compare Now »
Clear | Hide