Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Ambient temp. 0 degrees c to +60 degrees c; maximum voltage: 600 vac; iron core, 3% or 5% impedance based on fundamental current ratings
NSN
National Stock Number:
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
152.0 millimeters
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
51.0 millimeters single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
53.0 millimeters single mounting facility single center group
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
127.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
76.0 millimeters
MRC:
Indicates the type of inductance included on the item.ACYF
Inductance Type:
Fixed
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
3.00 microhenries single component single winding
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz single component or 60.0 hertz single component
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Panel; wsd: nimitz class cvn
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
3 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Slot single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
8.0 amperes ac single component single secondary and 12.0 amperes ac single component single secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 terminal block w/screws