Part Number 1503-8042

Delay Line

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
1503-8042
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
011157556
NSN
National Stock Number:
5999-01-115-7556 5999011157556
TXT
Description:
Delay Line
INC
INC
Item Name Code:
06373
INC
COM
Compliance:
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
A measurement of the longest dimension of the slot,in distinction from width.ABGD
Slot Length:
0.020 inches
MRC:
The number of fixed or adjustable facilities provided to adjust an item.ACZT
Adjustment Device Quantity:
1
MRC:
Indicates the type of drive provided for the adjustment device.ACZU
Adjustment Device Drive Type:
Slotted screw
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 1.374 inches and 1.434 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 0.485 inches and 0.515 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
0.300 inches
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
1.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
50.000 pounds per hour wet
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
100.000 ohms
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
Between 0.297 inches and 0.327 inches
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Terminal
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting provision(s).BBBW
Mounting Provision Arrangement Style:
Four position rectangular
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
1.500
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Lumped constant
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Variable
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.000 nanoseconds single section and 160.000 nanoseconds single section
MRC:
The number of segments into which a section is divided.CCDR
Segment Quantity Per Section:
1 single section
MRC:
The change in delay as a result of the temperature change per degree celsius.CCDT
Delay Time Variation Per Deg Celsius:
0.010 nanoseconds
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
32.0 nanoseconds
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
4 pin
MRC:
An overall measurement taken at right angles to the length of the slotted hole, in distinction from thickness.CDQK
Err Default:
Err default
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Selected and tested for an/tpx-42 (v) 10
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
00752-505174 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

Similar Delay Lines

« Miscellaneous Electrical and Electronic Components Catalog
Compare Now »
Clear | Hide