Part Number 164ER

Rota Electro-mechanical Actuator

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
164er
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
004741234
NSN
National Stock Number:
1680-00-474-1234 1680004741234
TXT
Description:
Rota Electro-mechanical Actuator
INC
INC
Item Name Code:
11006
INC
COM
Compliance:
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
2.4 and 2.6
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise and counterclockwise
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.0
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Electric
MRC:
The measurement of rotation,expressed in degrees.AWQL
Rotation In Deg:
180.0
MRC:
The rated torque of the output drive.AWQM
Output Drive Torque Rating:
100.0 inch-pounds
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
The means used to reset the thermal protector.AWQP
Thermal Protector Reset Method:
Automatic
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
An indication of the rotation of the angular shaft.AWTZ
Angular Shaft Rotation:
Limited
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
3.0 minutes on and 17.0 minutes off
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
26.0

Similar Rota Electro-mechanical Actuators

« Miscellaneous Aircraft Accessories and Components Catalog
Compare Now »
Clear | Hide