Part Number 167577

Thermal Relay
Stock Availability  condition code chart

Part number 167577 is in stock in the following quantities and conditions.

  • NS: 178
  • NE: 271
  • AR: 1

Note: Availability of this item was last updated 04/16/2024 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

Images

Reference images of this part
Picture of NSN 5945-00-666-0964
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
167577
Demil:
No
Shelf Life:
UOM:
NIIN:
006660964

Part Information
Four mtg holes 0.250 in. Length by 0.188 in. Width 0n 1.000 in. By 1.813 in. Mtg centers

NSN
National Stock Number:
5945-00-666-0964 5945006660964
TXT
Description:
Thermal Relay
INC
INC
Item Name Code:
03883
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.062 inches
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Double pole, single throw, normally closed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The highest voltage at which the contacts are rated for normal operating,expressed in volts.CYCS
Contact Maximum Voltage Rating In Volts:
440.0 ac
MRC:
The highest current at which the contacts are rated for normal operation,expressed in amps.CYCT
Contact Maximum Current Rating In Amps:
10.0 ac
MRC:
The amount of voltage for which the heater is designed,expressed in volts.CYCU
Heater Voltage Rating In Volts:
440.0
MRC:
A numeric value indicating the elapsed time interval of the item,expressed in seconds.CYCW
Delay Time In Seconds:
Between 32.0 fixed operate and 40.0 fixed release
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 pin

Similar Thermal Relaies

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide