Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Radio Frequency Amplifier
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+4.0 to 15.0 and +16.0 to 25.0 and +26.0 to 33.0
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
Vibration Resistance Amplitude:
0.06 inches total excursion and 0.04 inches total excursion and 0.02 inches total excursion
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
100.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0 to 50.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
170298-24930
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
1.0 feet
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
3.50 gigahertz operating channel and 3.70 gigahertz operating channel
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
3.16 milliwatts output
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
3.0 decibels
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms operating channel
MRC:
The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
Shock Pulse Duration Time:
6.0 milliseconds
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
25.0 single voltage