Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Rotary Relay
MRC:
The ability of an item to withstand a specified torque load without fracture.AAPL
Torque Load Rating:
35.00 inch-ounces
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.312 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.125 inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.281 in. Diameter mtg holes spaced 3.250 in. C to c
MRC:
The basic structure of the item.ALXF
Structural Design:
Sectional
MRC:
The alternating current values of root mean square potential which must be applied to the item for operation,expressed in volts.ANWD
Ac Operating Voltage Rating In Volts:
115.000
MRC:
The operating current for which the item is rated.APAM
Operating Current Rating:
0.620 amperes
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
220.000
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
2.000 amperes resistive
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
5.000 amperes
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
115.000
MRC:
The specific number of contact terminals included.APNG
Contact Terminal Quantity:
36
MRC:
The specific number of coil terminals included.APNH
Coil Terminal Quantity:
2
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
3.000 amperes
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
0.620 amperes
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Counterclockwise
MRC:
The opposition that the coil offers to the flow of direct current.BDFT
Coil Dc Resistance:
8.200 ohms
MRC:
The number of sections included.BWGP
Section Quantity:
6
MRC:
The number of coil winding(s) provided.CPWL
Coil Winding Quantity:
2
MRC:
An indication of the characteristic(s) of a winding.CPWM
Winding Characteristic:
Single wound untapped
MRC:
The amount of direct current resistance required to activate the coil pull-in.CPWP
Coil Pull-in Dc Resistance Rating:
8.200 ohms
MRC:
The amount of direct current resistance required to maintain operation of the coil hold-in.CPWQ
Coil Hold-in Dc Resistance Rating:
8.200 ohms
MRC:
The measurement of the shaft rotation,expressed in degrees.CPWT
Shaft Rotation In Deg:
25.500