Part Number 1801B-A-8

Signal Generator

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
1801b-a-8
Demil:
No
Shelf Life:
UOM:
NIIN:
011922783
NSN
National Stock Number:
6625-01-192-2783 6625011922783
TXT
Description:
Signal Generator
INC
INC
Item Name Code:
03901
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+1.000/+500.000 megahertz and +450.000/+950.000 megahertz
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
75.0 ohms
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 115.0 volts and 230.0 volts
MRC:
Indicates the type of modulation provided.AYYE
Modulation Type:
Am and fm
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
10.000 mhz or 2.000 pct of selected freq
MRC:
An indication of whether or not a crystal controlled feature is provided.BHFY
Crystal Controlled Feature:
Provided
MRC:
An indication of the calibrated signal range that is output by the item.BHFZ
Calibrated Signal Output Range:
Porm 0.25 db, 1 to plus 500 mhz
MRC:
Indicates the location of the modulator on the item.BHGD
Modulator Location:
External
MRC:
The number of complete cyclic changes,per unit of time,for which the modulation is rated.BHQD
Modulated Frequency Rating:
100.0 kilohertz

Similar Signal Generators

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide