Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Waveguide Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.880 inches
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Transfer
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+55.0 degrees celsius
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.20 single
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
1.5 kilowatts average 1st
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
1500.0 kilowatts peak 2nd
MRC:
The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
Minimum Crosstalk Rating In Decibels:
50.0 single
MRC:
The means provided for switching the actuator from one position to another.AKPC
Actuator Operating Method:
Relay
MRC:
The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
Actuator Current Type And Rating In Amps:
5.0 dc
MRC:
The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
Actuator Voltage In Volts:
28.0
MRC:
The time required for switching between any two adjacent positions.AKPP
Switching Time:
0.1 milliseconds
MRC:
Indicates the type of waveguide flange.AKPT
Waveguide Flange Type:
Choke
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
1
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Open off circuit termination
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches mounting facility hole
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches flange connection facility hole
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
24 threaded hole
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc flange connection facility hole
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc mounting facility hole