Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Flow Control Thermostat
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.759 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Flange
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Choke
MRC:
The predetermined pressure at which the item is calibrated to open.ADSV
Opening Pressure Setting:
52.5 pounds per square inch
MRC:
The length of a straight line which passes through the center of the largest diameter of an item,and terminates at the outside circumference.AGWM
Largest Outside Diameter:
1.600 inches
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Cool cooler oil
MRC:
The measured distance the valve travels.AMSD
Valve Travel Distance:
0.250 inches
MRC:
Indicates the type of thermostat.AWPA
Thermostat Type:
Bellows
MRC:
The rated temperature at which the item starts to open.AWTM
Opening Tempurature Rating:
150.0 degrees fahrenheit
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
165.0 degrees fahrenheit
MRC:
An indication of whether or not a spring operated pressure relief is provided.AWTP
Spring Operated Pressure Relief:
Provided
MRC:
The distance from the inside mounting surface to the valve seat.AWTR
Inside Mounting Surface To Valve Seat Distance:
2.182 inches
MRC:
The pressure setting at which the item will close.AWYH
Closing Pressure Setting:
Between 50.0 pounds per square inch and 55.0 pounds per square inch