Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
S Electrical Insulation Sleeving
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius and 80.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Mildew resistant and petroleum resistant and water resistant and hydraulic fluid
Main Body Inside Diameter:
0.260 inches after unrestricted recovery
Main Body Inside Diameter:
0.520 inches as supplied
First Branch Inside Diameter:
0.140 inches after unrestricted recovery
First Branch Inside Diameter:
0.260 inches as supplied
Second Branch Inside Diameter:
0.140 inches after unrestricted recovery
Second Branch Inside Diameter:
0.260 inches as supplied
Third Branch Inside Diameter:
0.140 inches after unrestricted recovery
Third Branch Inside Diameter:
0.260 inches as supplied
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
0.900 inches after unrestricted recovery and 1.100 inches after unrestricted recovery
Main Body Wall Thickness:
0.050 inches after unrestricted recovery and 0.070 inches after unrestricted recovery
First Branch Wall Thickness:
0.030 inches after unrestricted recovery and 0.050 inches after unrestricted recovery
Second Branch Wall Thickness:
0.030 inches after unrestricted recovery and 0.050 inches after unrestricted recovery
Third Branch Wall Thickness:
0.030 inches after unrestricted recovery and 0.050 inches after unrestricted recovery
Distance From Edge Of Main Body To Intersecting Centerlines:
0.740 inches after unrestricted recovery and 0.900 inches after unrestricted recovery
Main Bodylength:
1.640 inches after unrestricted recovery and 2.000 inches after unrestricted recovery
Angle Between Main Body And First Branch Centerlines In Deg:
25.0 after unrestricted recovery and 35.0 after unrestricted recovery
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1500 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Rubber, chloroprene
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber chloroprene class cr
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Transition-1 to 3 cables
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
200.0 volts per military /0.001 inch/