Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.635 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.875 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.280 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.500 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus resistant
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.187 inches single mounting facility
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.AFRG
Contact Material:
Silver
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the contact surface.AFRH
Contact Surface Treatment:
Gold flash
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The purpose for which the item is designed.AKSL
Purpose For Which Designed:
General
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The means of quenching an arc.APNQ
Arc Quenching Method:
Magnetic
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole single mounting facility
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
In-line single mounting facility
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
1 pole, single throw, normally open, double make, momentary action
MRC:
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
Operating Current Rating And Type:
84.0 milliamperes dc single winding
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the auxiliary nonpile-up contacts including the number of poles or forms.CSKP
Nonpile-up Auxiliary Contact Arrangement:
2 pole, double throw, one position momentary
MRC:
The highest voltage at which the auxiliary contacts are rated for normal operation,expressed in volts.CSQC
Auxiliary Contact Maximum Voltage Rating In Volts:
250.0 ac and 250.0 dc
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
24.0 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
2.0 amperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
500.0 dc
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
10.0 probe ac resistive load and 250.0 dual 16 stage dc resistive load
MRC:
The amount of electrical energy which the energizing element is capable of dissipating at its rated voltage and/or current during normal operation.CWJB
Energizing Element Power Rating:
2.0 watts
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contacts silver and contact surfaces gold
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold and silver
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
10 screw all functions