Part Number 200-104850

Coordinate Data Receiver

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
200-104850
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
012523390

Part Information
Wsensitivity: -132 db input; dynamic range: greater than 20 db; acquisition time: less that 90 seconds; time transfer noise error: less than 3 ns for 4 minutes smoothing; time transfer accuracy: less than 100 ns; time transfer determination interval: 6 seconds; 1-pps, k-kmz and time standard source bnc inputs; 1-pps and 5-mhz outputs; eia standard rs-232c output at 9600 bits/second; operation temperatue 40.0 to 130.0 degrees f; 275 watts; rack mounted; designed for ground use

NSN
National Stock Number:
5840-01-252-3390 5840012523390
TXT
Description:
Coordinate Data Receiver
INC
INC
Item Name Code:
11465
INC
COM
Compliance:
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
26.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 47.0 hertz and 63.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Time transfer system an/fsq-145
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Receives and tracks signals from the navstar global positioning satellite; corrects timing information; outputs a 1-mhz, 5-mhz, and 1 pulse/second signal
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Special circuit card assembly to provide coherent corrected/1-pps output

Similar Coordinate Data Receivers

« Except Airborne Radar Equipment Catalog
Compare Now »
Clear | Hide