Part Number 2014WREPAIRPARTSSPT

Surgical Instr Washer-sterilizer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
2014wrepairpartsspt
Demil:
No
Shelf Life:
UOM:
NIIN:
011456384

Part Information
Washer sterilizer surgical instrument pres stm 74.5 x 38.5 x 31.5"

NSN
National Stock Number:
6530-01-145-6384 6530011456384
TXT
Description:
Surgical Instr Washer-sterilizer
INC
INC
Item Name Code:
04497
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Cabinet
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
38.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
74.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
31.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
16.000 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
26.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
16.000 inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
The means by which the item is heated.BDWT
Heating Method:
Steam from remote steam source
MRC:
The number of shelves furnished with the item.BGZL
Shelf Quantity:
3
MRC:
The means by which the heat is transferred.BRXN
Heat Transfer Method:
Pressure steam
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Left or right hand door optional; three removable shelves; automatic control, microcomputer programmed; 50/60 hz; c/o sterilizer body; door assembly with locking device, controls, auxiliary components, and accessories; with five instrument trays 20-1/2 in. L, 13 in. W, 3 in. H (52.07 cm l, 33.02 cm w, 7.62 cm h); one pair of tray hooks; used in field assemblies
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel

Similar Surgical Instr Washer-sterilizers

« Hospital Furniture, Equipment, Utensils and Supplies Catalog
Compare Now »
Clear | Hide