Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Molding ports
NSN
National Stock Number:
TXT
Description:
S Electrical Insulation Sleeving
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Corrosion resistant and flame resistant and mildew resistant
Main Body Wall Thickness:
0.070 inches after unrestricted recovery
Main Bodylength:
1.630 inches after unrestricted recovery
Main Body Small End Inside Diameter:
0.340 inches after unrestricted recovery
Main Body Small End Inside Diameter:
1.420 inches as supplied
Main Body Large End Inside Diameter:
0.860 inches after unrestricted recovery
Main Body Large End Inside Diameter:
1.420 inches as supplied
Distance From Bottom Of Shoulder To Large End Of Main Body:
1.630 inches after unrestricted recovery
Distance From Top Of Shoulder To Small End Of Main Body:
0.630 inches after unrestricted recovery
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1500 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Semirigid
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, elastomer, rt-1325, raychem corp
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic, elastomer, rt-1325, raychem corp
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Boot-straight
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
300.0 volts per military /0.001 inch/