Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
203-16-404
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
000605903

Part Information
10 output channels 1 megahertz

NSN
National Stock Number:
5996-00-060-5903 5996000605903
TXT
Description:
Radio Frequency Amplifier
INC
INC
Item Name Code:
00446
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.688 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.406 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+52.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0 to 52.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Irregular
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
1702-195339-89536
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1.000 megahertz input channel
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
160.0 watts input
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
1.000 volts input
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
1.000 volts input preset
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
2.000 volts interstage
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
5.000 volts interstage preset
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
1.000 volts input
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
1.000 volts output
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms input channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms input channel
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Pin front
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
48.0 single voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
62.0 single voltage
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
11 pin external
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
120.0 1st voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
240.0 2nd voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Distribution amplifier, radio, except navigation, nonairborne