Part Number 203082

Liquid Level Gage Rod-breather

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
203082
Demil:
No
Shelf Life:
UOM:
NIIN:
011127659
NSN
National Stock Number:
6680-01-112-7659 6680011127659
TXT
Description:
Liquid Level Gage Rod-breather
INC
INC
Item Name Code:
22253
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.685 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.620 inches
MRC:
The length of a straight line which passes through the center of the mounting,and terminates at the outside circumference.ADHZ
Mounting Outside Diameter:
1.525 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
1905-01-009-1056
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the largest circumference.AGQA
Largest Diameter:
2.690 inches
MRC:
The distance of separation from the end of the rod to the start of the scale graduation.BJFJ
Distance From Rod End To Scale Graduation:
1.500 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the rod end and at the start of the breather.BJFS
Rod Length From End To Breather:
15.065 inches
MRC:
A measurement taken at right angles to the length of the rod measuring portion,in distinction from thickness.BJFW
Rod Measuring Portion Width:
0.375 inches
MRC:
A measurement of the smallest dimension of the rod measuring portion,in distinction from length or width.BJFX
Rod Measuring Portion Thickness:
0.125 inches
MRC:
Indicates the type of breather mounting provided.BJFY
Breather Mounting Type:
Unthreaded
MRC:
Indicates the type of breather locking device provided with the item.BJFZ
Err Default:
Err default
MRC:
The inscription affixed to or stamped on the scale,excluding part number.BKBF
Scale Inscription:
Full and low and lube oil
MRC:
An indication of whether or not breather filter material is provided.BKBG
Breather Filter Material:
Provided
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Metal

Similar Liquid Level Gage Rod-breathers

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments Catalog
Compare Now »
Clear | Hide