Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Terminal mounted
NSN
National Stock Number:
TXT
Description:
Slide Switch
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Hole mounted
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.986 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.485 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.380 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.986 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.380 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.285 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The number of actuators provided in the item for selection of switching positions.AFCG
Switch Actuator Quantity:
9
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
0.050 inches
Actuator Height:
0.035 inches
MRC:
A measurement taken at right angles to the length of the actuator,in distinction from thickness.AFUT
Actuator Width:
0.080 inches
MRC:
The relationship between the actuator position and the actuator action /maintained or momentary/.AFUX
Actuator Position-action Relationship:
Up position maintained and down position maintained
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
24.0 dc
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
9 pole, single throw, both positions maintained single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
50.000 milliamperes resistive dc
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contact arm surfaces gold
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
18 printed circuit