Part Number 2101

Pulse Generator
Description

Seal

Stock Availability  condition code chart

Part number 2101 is in stock in the following quantities and conditions.

  • NS: 643
  • NE: 303
  • AR: 7
  • OH: 1
  • SV: 1

Note: Availability of this item was last updated 06/06/2024 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
2101
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
000016916
NSN
National Stock Number:
6625-00-001-6916 6625000016916
TXT
Description:
Pulse Generator
INC
INC
Item Name Code:
00411
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
14.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.875 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0 to 50.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
25.0 megahertz input channel
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Continuous
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
10.000 volts input
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms input channel
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
20.000 nanoseconds input channel
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
400.000 milliseconds input channel
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
5.000 nanoseconds input channel
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
5.000 nanoseconds input channel
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Negative input channel
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive input channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Input channel pulse
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Pulse, gate
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Receptacle, coaxial front
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
440.0 single voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
48.0 single voltage
MRC:
A designation of the function which is calibrated.BJBS
Calibration Function:
Impedance
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
2 receptacle, coaxial internal
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
272.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
90.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Bb-1.1
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
91-02-19

Similar Pulse Generators

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
  • 260
    NSN: 6625-00-001-6918
  • 600A
    NSN: 6625-00-001-6919
  • 6550-1
    NSN: 6625-00-001-6920
  • LAA3E-T
    NSN: 6625-00-001-6922
  • SAMME292
    NSN: 6625-00-001-6923
Compare Now »
Clear | Hide