Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Line Electro-mechanical Actuator
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-54.0 degrees celsius and 71.0 degrees celsius
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.880 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.060 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.41
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
Between 0.970 inches and 1.030 inches
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
100.0 pounds static
MRC:
The compression stress applied to the item under load conditions.AWTC
Compression Load Rating:
100.0 pounds static
MRC:
The rate of linear travel per unit of time.AWTE
Rated Stroke Velocity:
0.800 inches per second and 1.400 inches per second
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
6.0 minutes on and 54.0 minutes off
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Unthreaded mounting holes
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
26.0
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Airconditioning, aircraft