Part Number 21189-2

Capillary Indicating Thermometer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
21189-2
Demil:
No
Shelf Life:
UOM:
NIIN:
008042032
NSN
National Stock Number:
6685-00-804-2032 6685008042032
TXT
Description:
Capillary Indicating Thermometer
INC
INC
Item Name Code:
07419
MRC:
The length of a straight line which passes through the center of a case,and terminates at the circumference.ABKJ
Case Diameter:
3.530 inches
MRC:
The length of a straight line which passes through the center of a mounting bolt circle,and terminates at the circumference.AFFL
Mounting Bolt Circle Diameter:
3.125 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Support equipment, f-4 aircraft; support equipment, h-1 helicopter
MRC:
The length of a straight line which passes through the center of the dial,and terminates at the circumference.ASSP
Dial Diameter:
2.500 inches
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Dial
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 flange
MRC:
None.BKCG
Bulb Tip Length:
2.140 inches
MRC:
An indication of the medium used to actuate the item.BKCM
Actuating Medium:
Vapor
MRC:
The number of bulbs provided.BKCT
Bulb Quantity:
1
MRC:
Indicates the type of bulb provided with the item.BKCW
Bulb Type:
Flexible capillary
MRC:
Indicates the type of bulb connection provided with the item.BKCX
Bulb Connection Type:
Union
MRC:
A measurement of the longest dimension of the active portion of an item,in distinction from width.BKCY
Active Portion Length:
2.140 inches
MRC:
The length of a straight line which passes through the center of the active portion of a circular figure or body,and terminates at the circumference.BKCZ
Active Portion Diameter:
0.440 inches
MRC:
The means used to connect the indicator.BLQF
Indicator Connection Method:
Flexible tube
MRC:
A measurement of the longest dimension of the flexible tube,in distinction from width.BLQG
Flexible Tube Length:
120.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the bulb.CRSK
Bulb Style:
Plain bulb w/rigid extension
MRC:
The minimum and maximum numeric values representing the type of scale measurement.CSYG
Scale Measurement Range:
+0.000/+100.000 degrees fahrenheit
MRC:
None.CSYH
Bulblength:
2.700 inches
MRC:
Indicates the type and number of pointer(s) or pen(s).CSYJ
Pointer/pen Type And Quantity:
1 indicating single
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel meter case
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Front flanged and hinged ring, back connection

Similar Capillary Indicating Thermometers

« Pressure, Temperature and Humidity Measuring and Controlling Instruments Catalog
Compare Now »
Clear | Hide