Part Number 225

Humidity-temperature Recorder

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
225
Demil:
No
Shelf Life:
UOM:
NIIN:
000916229

Part Information
X2 seperate channels, humidity and temperature; accuracy temp channel +/- 1 degrees f and humidity channel +/- 4 rh between 20 and 80 rh at 77 degrees f; temp coeffecient -0.2rh/deg f; response time temp channel 1 second to 63%; humidity channel 30 seconds to 63%; sampling rate 8 seconds for one complete cycle 4 second intervals between humidity and temp; mounting: brackets for wall mounting and panel mounting; weight 4 lbs; chart paper style p, pressure sensitive, speed 1/2 inch per four or 1 ft per day; size 63 ft l ong by 2 5/16 inches useable width; paper life 9 weeks; recorder may be placed on desk or table or mounted on wall or panel; sensor 6 ft cable; recorder case material die cast aluminum; paper has easy to read straight line grids

NSN
National Stock Number:
6685-00-091-6229 6685000916229
TXT
Description:
Humidity-temperature Recorder
INC
INC
Item Name Code:
21810
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
6.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.625 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.625 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Strip chart paper 1; sensor extension cable 1
MRC:
The minimum to maximum limits of operation for which the item is rated.ANBG
Operating Range:
+10.0/+90.0 percent and +60.0/+90.0 degrees fahrenheit
MRC:
The minimum to maximum limits of operation for which the item is rated.ANBG
Operating Range:
+10.0 to 90.0 percent and +60.0 to 90.0 degrees fahrenheit
MRC:
Indicates the type of information the item will record.ANBH
Information Recorded:
Relative humidity and temperature
MRC:
The means by which the item records information.ANBK
Recording Method:
Pressure sensitive paper
MRC:
The means by which the chart is driven.ANBL
Chart Drive Method:
Electric motor
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Humidity-temperature Recorders

« Pressure, Temperature and Humidity Measuring and Controlling Instruments Catalog
Compare Now »
Clear | Hide