Part Number 231-0092-000

Dynamotor

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
231-0092-000
Demil:
No
Shelf Life:
UOM:
NIIN:
005078220
NSN
National Stock Number:
6125-00-507-8220 6125005078220
TXT
Description:
Dynamotor
INC
INC
Item Name Code:
04847
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
3 threaded hole
MRC:
The acceptable time limits for the item.BFLT
Time Interval:
5.0 seconds on and 5.0 seconds off
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Natural convection ventilated
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
40.0 ambient degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
7000.0 single no load
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
0.200 single output
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
9.000 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
150.0 line to neutral low output or 250.0 line to neutral high output
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
27.5 line to neutral single input

Similar Dynamotors

« Converters Electrical Rotating Catalog
Compare Now »
Clear | Hide